Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Microbiol ; 55(7): 2180-2187, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28468860

RESUMO

Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection.


Assuntos
Sangue/virologia , Infecções por HTLV-I/diagnóstico , Infecções por HTLV-II/diagnóstico , Vírus Linfotrópico T Tipo 1 Humano/isolamento & purificação , Vírus Linfotrópico T Tipo 2 Humano/isolamento & purificação , Programas de Rastreamento/métodos , Europa (Continente) , Humanos , Japão , Medições Luminescentes/métodos , Sensibilidade e Especificidade
2.
Diagn Microbiol Infect Dis ; 70(4): 479-85, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21658874

RESUMO

A low initial reactive rate for screening assays is important for time- and cost-effective infectious disease testing. Therefore, the new ARCHITECT HBsAg Qualitative screening assay, in conjunction with the new ARCHITECT HBsAg Qualitative Confirmatory assay, was introduced. As the role of hepatitis B surface antigen (HBsAg) as surrogate marker for HBV resolution and the monitoring of drug effectiveness are becoming increasingly important, the established ARCHITECT HBsAg Quantitative assay remains available on the market. Precision, sensitivity, and specificity of the newly developed screening assay were in the range of established HBsAg assays. Seroconversion sensitivity was slightly superior compared to other commercially available assays. An initial reactive rate of 0.2% (without HBsAg-confirmed positive samples of 0.17%) for the ARCHITECT HBsAg Qualitative assay was observed. As the new screening assay is a 1-step assay format, the "high-dose hook effect" was investigated to assess the risk of false-negative results, but even very high positive HBsAg samples obtained signals clearly above the cutoff.


Assuntos
Sangue/virologia , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Programas de Rastreamento/métodos , Virologia/métodos , Humanos , Sensibilidade e Especificidade
3.
Transfusion ; 48(9): 1853-61, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18513254

RESUMO

BACKGROUND: The Roche cobas TaqScreen test, an automated, multiplex nucleic acid test for blood screening for hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA, human immunodeficiency virus type 1 (HIV-1) groups M and O, and HIV-2 RNA, on the cobas s 201 platform, was evaluated by six European blood screening laboratories. STUDY DESIGN AND METHODS: The 95 percent limit of detection (LOD) of the cobas TaqScreen test for HBV, HCV, and HIV-1, using dilutions of the WHO International Standards, were evaluated. The clinical performance was determined by testing between 2000 to 6000 routine donor samples. Some laboratories evaluated the robustness, cross-contamination, and workflow. RESULTS: The mean 95 percent LOD (95% lower and upper confidence intervals) for HBV, HCV, and HIV-1 across all the laboratories were 3.8 (range, 3.0-5.2), 10.8 (range, 8.4-14.4), and 56.7 (range, 43.0-79.2) IU/mL, respectively. A total of 23,716 donors were tested in pools of 6. Fourteen initially reactive pools were detected, of which 6 contained a reactive donation, giving a positive predictive value of the pool results of 43 percent. One of the reactive donations was a HBV yield case (hepatitis B surface antigen-negative/anti-HBc-positive). Evaluation of the workflow for the system showed that an optimized batch loading in which a pipettor (Hamilton Microlab Star IVD) was utilized to half capacity was better than a full batch loading. CONCLUSION: The 95 percent LOD for the three viruses were comparable to those obtained by Roche. The test and platform were shown to be sensitive, specific, flexible, and robust.


Assuntos
Doadores de Sangue , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Programas de Rastreamento/métodos , DNA Viral/genética , HIV-1/genética , Hepacivirus/genética , Hepatite B/diagnóstico , Hepatite B/virologia , Vírus da Hepatite B/genética , Hepatite C/diagnóstico , Hepatite C/virologia , Humanos , Programas de Rastreamento/instrumentação , Técnicas de Amplificação de Ácido Nucleico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA